HomeOIL WATER SEPARATORSMART TURBIDITY For Turbidity Monitor Rivertrace

SMART TURBIDITY For Turbidity Monitor Rivertrace

The SMART Turbidity monitor accurately analyses the cloudiness of a fluid and outputs the turbidity value in NTU.

The SMART Turbidity monitor accurately analyses the cloudiness of a fluid and outputs the turbidity value in NTU.

Measuring the turbidity of water is a critical component of oil-in-water monitoring, ensuring compliance with stringent marine environmental regulations.

By utilising the “Smart Cell” Detector Array Technology, developed by Rivertrace, the monitor accurately analyses the quality of the sample stream and outputs the turbidity value in nephelometer turbidity units (NTU) Turbidity is the cloudiness or haziness of a fluid caused by large numbers of individual particles.

A manual cell cleaning device is included as standard to easily enable routine maintenance and prevent Optical cell fouling which is recognised as a leading cause of monitor malfunction or incorrect reading. By simple operation of the manual cleaning device, the measuring cell remains in optimum operating condition.
Replacement calibrated measuring cells can be purchased for easy change over and calibration verification kits enable the user to demonstrate the monitor is within factory calibration.

The Smart Turbidity Monitor is also available for Hazardous area Environments classified as Zone 1 & 2.

SMART TURBIDITY APPLICATIONS

  • Sewage Treatment Plant Effluent Monitor
  • Brewing Quality Monitor
  • Groundwater Effluent

    SMART TURBIDITY For Turbidity Monitor Rivertrace Model
    SMART TURBIDITY For Turbidity Monitor Rivertrace Model

SMART TURBIDITY  OPTIONS

All options can be ordered from new or retrofitted to existing Rivertrace Smart Cell monitors.

SMART TURBIDITY Specification

MEASUREMENT
Clean water calibration : +/- 2ppm of factory set values
Turbidity range : 0 – 100 NTU
Accuracy : +/- 1 NTU
Response time : < 5 sec
ALARMS
Alarm 1 set point : 1 – 100 NTU user adjustable
Alarm 2 set point : 1 – 100 NTU user adjustable
Alarm 1 delay : 0 – 5 seconds user adjustable
Alarm 2 delay : 0 – 600 seconds user adjustable
INPUT / OUTPUT
Analogue output : Active 4-20mA / 0 – 20mA
DATA STORAGE AND RETRIEVAL
Calibrate on data storage : Stored in cell assembly
SYSTEM AND SUPPLY
Supply voltage : 115 or 230V AC, 50 – 60Hz (24V AC & 12V DC available)
Supply voltage Consumption : < 50 VA
Supply voltage tolerance : +/- 15%
Projected life : > 50,000 hrs
Protection class : IP 65
Weight : 3.2 Kg / 7.05lb

 

Read more :

  1. SMART 50M For Oil in Water Detector
  2. SMART PFM 107 OIL IN WATER MONITOR RIVERTRACE
  3. Spare Parts Oil Content Monitor Rivertrace
  4. The SMART Hub Control Monitor Water and Waste Water Rivertrace
RELATED ARTICLES

LEAVE A REPLY

Please enter your comment!
Please enter your name here

- Advertisment -
Google search engine

Most Popular

Recent Comments