HomeOIL WATER SEPARATORSMART 50M For Oil in Water Detector

SMART 50M For Oil in Water Detector

The SMART 50M is a versatile oil in water monitor suitable for high temperature and pressure in both marine and industrial applications.

The SMART 50M is a versatile oil in water monitor suitable for high temperature and pressure in both marine and industrial applications.

The SMART 50M is a versatile and sophisticated oil-in-water detector. The monitor is designed for high temperature and high-pressure sample measurements in marine and industrial applications, across multiple ranges of oil concentration.

The monitor has two versions available to suit different oil ranges – low and medium. Combined with proprietary measuring cell, autoclean capability and auto-zeroing functionality, this oil-in water detector has minimal maintenance requirements, producing highly accurate measurements consistently, as the measuring cell is kept free from fouling.

The oil-in-water detector uses a nephelometry based detection technique and sophisticated algorithms to detect oil content in the sample stream. 

An internal data recorder will log the following data – oil concentration, sample pressure, sample temperature, fault status alarm and run status.

The Smart 50M can provide the Oil Concentration value to a DCS or PLC using a 4-20mA output.

As standard the following data is available :

  • Oil Concentration
  • Sample Pressure
  • Sample Temperature
  • Fault Status
  • Alarm and Run states

Oil in Water Detector Applications

  • Hydrocarbon Leak Detection
  • Lube Oil Cooler Monitoring
  • Boiler Feed Protection
    Heat Exchanger Leak Detection
    Industrial Wastewater/Groundwater discharge.

Oil in Water Detector Specification

Ranges : Low range 0 – 10ppm
Medium range  0 – 200ppm
Accuracy : Low range  +/- 0.5ppm
Medium range  +/- 5 ppm
Alarm 1 Operating Point : Low range 1 – 10 ppm
Medium range 1 – 200 ppm
Alarm 2 Operating Point : Low range 1 – 10 ppm
Medium range 1 – 200 ppm
Alarm 1 Operating Delay : 1 – 15 seconds
Alarm 2 Operating Delay : 1 – 600 seconds
Alarm contact rating : 8 AMP @230VAC
Output signal : 4-20 mA
Ambient temperature : 1-60 °C / 34 – 122 F
Humidity : Max 98% non condensing
Sample temperature : 1 – 95 °C / 34-203 F
Sample Flow : 0.3 – 3 Ltrs per min / 0.079 – 0.79 Gal per min
Sample Pressure : 1.0 Bar Minimum / 14.50 Psi
3.0 Bar Nominal / 43.50 Psi
Clean Water requirements : 0.3 – 3L per min / 0.079 – 0.79 Gal per min for ‘zeroing’
Weight : 15kg / 33.07 lb
Size : 500 x 360 x 150mm / 19.7” x 14.2” x 5.9”
Supply voltage : 115 – 230 VAC
Power consumption : 15 VA
Degree of Protection : IP56
Approvals : Tested to EN61010 EN61326 (CE), c UL us.

 

Read more :