HomeFuel ControlDFM S7 Wireless fuel flow meter for measurement of liquid fuel and...

DFM S7 Wireless fuel flow meter for measurement of liquid fuel and mineral oil consumption

DFM S7 and DFM DS7 wireless fuel flow meters are designed for direct measurement of liquid fuel and mineral oil consumption with a kinematic viscosity of 1.5 to 6.0 mm2/s, as well as for monitoring fuel consumer operating time. DFM S7/DS7 flow meters can be used independently or as part of vehicle telematics and remote monitoring systems for vehicles, stationary engines, diesel generator sets, boilers and other fuel-consuming equipment.

The flow meters use S7 Technology for wireless data transfer via Bluetooth Low Energy (Bluetooth 4.1). The BLE module transmits current readings every 5 seconds in advertising mode, allowing the data to be received simultaneously by compatible telematics units and GPS trackers, Bluetooth displays, smartphones and tablets within the signal range.

DFM S7 Wireless Fuel Flow Meter Core Features

  • BLE-radio mode – data is transmitted simultaneously to multiple receiving devices
  • built-in battery – the flow meter operates without an external power supply
  • ultra-low power consumption enables autonomous operation for up to 5 years
  • explosion and fire safety without additional intrinsic safety barriers
  • no signal cable – enhanced resistance to vandalism and accidental cable damage

DFM S7 Wireless Fuel Flow Meter Tasks

Fuel theft prevention Preventing fuel theft
Actual fuel consumption monitoring Fuel consumption monitoring
Engine testing for fuel consumption
Engine operating time monitoring Machine running time tracking

Models of wireless fuel flow meters

Single-chamber models (DFM 50S7, DFM 100S7, DFM 250S7 and DFM 500S7) measure fuel consumption directly in the engine supply fuel line. They can operate autonomously or as part of a telematics system. The flow meters are designed for fuel consumption monitoring of road and off-road vehicles, railway vehicles, marine vessels, diesel generator sets and stationary machinery. Depending on the model, the measuring range covers 1 to 500 L/h.
Differential models (DFM 100DS7, DFM 250DS7 and DFM 500DS7) measure fuel consumption as the difference between the fuel volumes flowing through the feed and reverse fuel lines. They are designed for road and off-road vehicles, railway vehicles, marine vessels and stationary equipment with up-to-date diesel engines equipped with Common Rail fuel injection systems or pump-injector units. Depending on the model, the measuring range in each fuel line is up to 100, 250 or 500 L/h.

Fuel consumption and operating time Counters

  • Hourly fuel consumption, L/h
  • Total fuel consumption, L
  • Total fuel consumption in “Idle” mode
  • Total fuel consumption in “Optimal” mode
  • Total fuel consumption in “Overload” mode
  • Fuel consumption in “Tampering” mode, L
  • Engine operation mode by fuel rate
  • Fuel temperature
  • Battery charge level
  • Total operating time, h
  • Total operating time in “Idle” mode, h
  • Total operating time in “Optimal” mode, h
  • Total operating time in “Overload” mode, h
  • Operating time in “Tampering” mode, h
  • Operating time in “Interference” mode, h

Bluetooth data transfer to a telematics unit or GPS tracker

he flow meter continuously transmits fuel consumption readings, data from Counters, information on Events, engine operation modes, Parameters and flow meter malfunctions in the “advertising” (BLE-radio) mode. Using S7 Technology, the data can be received by all compatible devices within the operating range of the flow meter BLE module.

Bluetooth data transfer to a telematics unit or GPS tracker
Bluetooth data transfer to a telematics unit or GPS tracker

Fuel consumption control via Bluetooth on a smartphone

To receive data from DFM S7 wireless fuel flow meters on a smartphone or tablet running Android 5.0 or higher, use the Fuel Rate Monitor mobile application. Its functionality allows the user to :

  • monitor fuel consumption and fuel temperature in real time
  • account for total fuel consumption and fuel consumption by operating mode
  • account for fuel consumer operating time
  • display the current operating mode based on fuel consumption
  • view a real-time graph of hourly (instant) fuel consumption
  • monitor active flow meter malfunctions
  • check the charge level of the built-in battery
  • log hourly fuel consumption and fuel temperature readings
  • perform operations with the flow meter profile

    Fuel consumption control via Bluetooth on a smartphone
    Fuel consumption control via Bluetooth on a smartphone

Fuel flow meter for ships using NMEA 2000

MasterCAN S7 NMEA data converter continuously receives data from DFM S7 fuel flow meters using S7 Technology within a range of up to 50 m. The converter processes the received data and converts it into NMEA 2000 PGNs. Fuel consumption, fuel temperature and fuel consumer operating time can then be transmitted over the vessel’s NMEA 2000 network to compatible onboard devices.

Fuel flow meter for ships using NMEA 2000
Fuel flow meter for ships using NMEA 2000

DFM S7  part number description for ordering

DFM S7 part number description for ordering
DFM S7 part number description for ordering

The designation U is relevant only for single-chamber models.

Models are delivered by special order.

Technical specifications of wireless flow meters

Max pressure, bar 25
Wireless data transfer interface Bluetooth 4.1
Transmitter power (Tx Power), dBm +4
Maximum distance between the flow meter and the receiving device, m 15 (with metal/concrete partitions at the installation site)
45 (within line-of-sight range)
Autonomous operating time from the built-in battery, years up to 5*
Operating temperature range, °C −40…+85
Ingress protection rating (IP Code) IP54

* At a constant ambient temperature of +20 °C. Under actual operating conditions with temperature fluctuations, autonomous operating time may be reduced, but is guaranteed to be at least 2 years.